South Shields Interceptor Bs/104
Storm overflow operated by Northumbrian Water. The source names River Don as the receiving water.
- 90
- Spills in 2025
- 467.2
- Recorded hours
- 100%
- Monitor operation
- 2
- Years listed
The reported spill count was 18 lower than in 2024. This compares event counts, not discharge volume.
Checking the latest monitor report…
How it compares in 2025
South Shields Interceptor Bs/104 recorded 90 spills in 2025. That is more than 97% of the 14,239 overflows in England with a reported figure, and ranks 355th nationally. Among Northumbrian Water overflows it ranks 17th of 1,559; the median Northumbrian Water overflow recorded 11 spills. On the Don from Source to Tidal Limit waterbody it ranks 2nd of 34.
| Group | Rank by spills | Median spills | Median hours |
|---|---|---|---|
| This outlet | – | 90 | 467.2 |
| England | 355th of 14,239 | 11 | 22.3 |
| Northumbrian Water | 17th of 1,559 | 11 | 15.6 |
| Don from Source to Tidal Limit | 2nd of 34 | 5.5 | 3.4 |
Rank 1 has the most spills. Equal counts share a rank. Only overflows with a reported count are ranked. Counts do not measure volume, so a higher rank does not mean more sewage.
Annual spill history
| Year | Spills | Duration | Monitor operation | Source |
|---|---|---|---|---|
| 2025 | 90 | 467.2 hours | 100% | Official data |
| 2024 | 108 | 870.5 hours | 100% | Official data |
A missing figure means the source did not provide a usable value. A zero is shown as zero. Monitor operation below 90% can make comparison less reliable.
Outlet details
- Water company
- Northumbrian Water
- Outlet type
- Storm overflow on the sewer network
- Permit
- 235/B/0170
- Activity reference
- A1
- Grid reference
- NZ3343764674
- Waterbody ID
- GB103023075690Official waterbody record ↗
- Location source
- Official annual grid reference
- Location precision
- About 1 metres
- Location note
- Unknown
About the name and type
The annual return lists this asset as “SO on sewer network”: storm overflow on the sewer network. The return places this overflow on the sewer network.
The waterbody link opens the Environment Agency record for the exact ID in the return. It is a source lookup; we do not import its classification.
Where it is
The recorded position is about 0.6 km north of the Jarrow reference point in the ONS built-up areas data.
Area and water pages
- Gateshead area →
- Follingsby area →
- Springwell area →
- Washington area →
- Hebburn area →
- Wallsend area →
- Longbenton area →
- Jarrow area →
- Boldon Colliery area →
- Killingworth area →
- Shiremoor area →
- Backworth area →
- East Boldon and West Boldon area →
- Tynemouth area →
- South Shields area →
- Don from Source to Tidal Limit waterbody →
Check the official record
Public access to this outlet is unknown. Do not enter restricted land or use this page as a route guide.
Open official source ↗Other outlet records nearby
- Tyneside CSO (No B5/301)Current status unknown
Northumbrian Water · Don
- Tyneside CSO B5/201Current status unknown
Northumbrian Water · River Don
- Don Valley Pumping StationCurrent status unknown
Northumbrian Water · Don
- Cemetery Road CSOCurrent status unknown
Northumbrian Water · Don
Questions about South Shields Interceptor Bs/104
- Who operates South Shields Interceptor Bs/104?
- Northumbrian Water is the operator named in the annual record. The permit reference is 235/B/0170.
- Where does South Shields Interceptor Bs/104 discharge?
- The source names River Don as the receiving water. This does not show how far a discharge travelled.
- How many times did South Shields Interceptor Bs/104 spill in 2025?
- The 2025 return records 90 counted spill events and 467.2 hours of recorded discharge. Spills are counted with the 12/24-hour method, so this is not a count of every start signal.
- Can I trust the 2025 figures for this outlet?
- The monitor worked for 100% of the reporting period, so the annual figures cover most of the year. They still do not measure discharge volume.
- Is South Shields Interceptor Bs/104 discharging right now?
- This record is linked to a company live feed. The panel above shows the latest report we hold, with its date. That report can be old, and the monitor can be offline, so check the date before relying on it. A report that no discharge is taking place is not a water-quality result.
- How accurate is the map marker?
- The marker comes from the grid reference in the official annual return, which is accurate to about 1 metres. It shows the recorded outlet position, not the extent of any discharge.
- What kind of outlet is South Shields Interceptor Bs/104?
- The annual return lists the asset type as “SO on sewer network”, which means storm overflow on the sewer network. The return places this overflow on the sewer network.
- How does South Shields Interceptor Bs/104 compare with other overflows?
- South Shields Interceptor Bs/104 recorded 90 spills in 2025. That is more than 97% of the 14,239 overflows in England with a reported figure, and ranks 355th nationally. Among Northumbrian Water overflows it ranks 17th of 1,559; the median Northumbrian Water overflow recorded 11 spills. On the Don from Source to Tidal Limit waterbody it ranks 2nd of 34. Ranks compare counted spill events only. They do not compare volume or harm.
- Does zero spills mean the water was safe?
- No. A zero means the annual return recorded zero counted spill events for this outlet and year. It is not a water-quality test, and pollution can come from other sources.