Lorna Irwin Spst Pscsoeo Combe Martin
Storm overflow operated by South West Water. The source names River Umber (S) as the receiving water.
- 0
- Spills in 2025
- 0
- Recorded hours
- 79%
- Monitor operation
- 5
- Years listed
Checking the latest monitor report…
How it compares in 2025
Lorna Irwin Spst Pscsoeo Combe Martin recorded no spills in 2025. It is one of 2,231 overflows in England with a reported count of zero, out of 14,239 with a count.
The monitor worked for 79% of 2025, so this count may be low and its rank may understate activity.
| Group | Rank by spills | Median spills | Median hours |
|---|---|---|---|
| This outlet | – | 0 | 0 |
| England | 12,009th of 14,239 | 11 | 22.3 |
| South West Water | 1,180th of 1,357 | 21 | 39.4 |
| Umber | 3rd of 3 | 19 | 344 |
Rank 1 has the most spills. Equal counts share a rank. Only overflows with a reported count are ranked. Counts do not measure volume, so a higher rank does not mean more sewage.
Annual spill history
| Year | Spills | Duration | Monitor operation | Source |
|---|---|---|---|---|
| 2025 | 0 | 0 hours | 79%Low coverage | Official data |
| 2024 | 0 | 0 hours | 100% | Official data |
| 2023 | Unknown | Unknown | Unknown | Official data |
| 2022 | 20 | 375 hours | 100% | Official data |
| 2021 | 51 | 777 hours | 100% | Official data |
A missing figure means the source did not provide a usable value. A zero is shown as zero. Monitor operation below 90% can make comparison less reliable.
Outlet details
- Water company
- South West Water
- Outlet type
- Storm discharge at a pumping station
- Permit
- 2674
- Activity reference
- A1
- Grid reference
- SS57884702
- Waterbody ID
- GB108051020440Official waterbody record ↗
- Location source
- Official annual grid reference
- Location precision
- About 10 metres
- Location note
- Unknown
About the name and type
The annual return lists this asset as “Storm discharge at pumping station”: storm discharge at a pumping station. The overflow is at a pumping station that moves sewage through the network.
The waterbody link opens the Environment Agency record for the exact ID in the return. It is a source lookup; we do not import its classification.
Where it is
The recorded position is about 0.6 km north-east of the Combe Martin reference point in the ONS built-up areas data.
Designated bathing waters within 3 km in a straight line:
Distance does not show that water from this outlet reaches a bathing water. Check the official bathing-water profile for its classification and advice.
Area and water pages
Check the official record
Public access to this outlet is unknown. Do not enter restricted land or use this page as a route guide.
Open official source ↗Other outlet records nearby
- Cross Street SPS Pscsoeo Combe MartinCurrent status unknown
South West Water · River Umber
- Pack Of Cards CSO Combe MartinCurrent status unknown
South West Water · River Umber (S)
- Berrynarbor Spst Pscsoeo BerrynarborCurrent status unknown
South West Water · Unnamed Stream (S)
- Hele Bay SPS Pscsoeo IlfracombeCurrent status unknown
South West Water · Hele Bay - Bristol Channel
Questions about Lorna Irwin Spst Pscsoeo Combe Martin
- Who operates Lorna Irwin Spst Pscsoeo Combe Martin?
- South West Water is the operator named in the annual record. The permit reference is 2674.
- Where does Lorna Irwin Spst Pscsoeo Combe Martin discharge?
- The source names River Umber (S) as the receiving water. This does not show how far a discharge travelled.
- How many times did Lorna Irwin Spst Pscsoeo Combe Martin spill in 2025?
- The 2025 return records 0 counted spill events and 0 hours of recorded discharge. Spills are counted with the 12/24-hour method, so this is not a count of every start signal.
- Can I trust the 2025 figures for this outlet?
- The monitor worked for 79% of the reporting period. Below 90%, some events can be missed, so the count and hours may understate activity.
- Is Lorna Irwin Spst Pscsoeo Combe Martin discharging right now?
- This record is linked to a company live feed. The panel above shows the latest report we hold, with its date. That report can be old, and the monitor can be offline, so check the date before relying on it. A report that no discharge is taking place is not a water-quality result.
- How accurate is the map marker?
- The marker comes from the grid reference in the official annual return, which is accurate to about 10 metres. It shows the recorded outlet position, not the extent of any discharge.
- What kind of outlet is Lorna Irwin Spst Pscsoeo Combe Martin?
- The annual return lists the asset type as “Storm discharge at pumping station”, which means storm discharge at a pumping station. The overflow is at a pumping station that moves sewage through the network.
- How does Lorna Irwin Spst Pscsoeo Combe Martin compare with other overflows?
- Lorna Irwin Spst Pscsoeo Combe Martin recorded no spills in 2025. It is one of 2,231 overflows in England with a reported count of zero, out of 14,239 with a count. Ranks compare counted spill events only. They do not compare volume or harm.
- Does zero spills mean the water was safe?
- No. A zero means the annual return recorded zero counted spill events for this outlet and year. It is not a water-quality test, and pollution can come from other sources.