Sewage Map

Cuxton CEO - 111607

Storm overflow operated by Southern Water. The source names The Tidal River Medway as the receiving water.

0
Spills in 2025
0
Recorded hours
100%
Monitor operation
5
Years listed

The reported spill count was 2 lower than in 2024. This compares event counts, not discharge volume.

Current status unknown

We do not have a live report for this outlet. Its annual spill records are shown below.

Open official annual data ↗

How it compares in 2025

Cuxton CEO - 111607 recorded no spills in 2025. It is one of 2,231 overflows in England with a reported count of zero, out of 14,239 with a count.

GroupRank by spillsMedian spillsMedian hours
This outlet–00
England12,009th of 14,2391122.3
Southern Water801st of 975717
Medway64th of 8642.3

Rank 1 has the most spills. Equal counts share a rank. Only overflows with a reported count are ranked. Counts do not measure volume, so a higher rank does not mean more sewage.

Annual spill history

0202102022120232202402025
From 2021 to 2025, the reported count went from 0 to 0 spills. The highest count was 2 in 2024 and the lowest was 0 in 2021.
YearSpillsDurationMonitor operationSource
202500 hours100%Official data
202424.5 hours99.9%Official data
202312.3 hours100%Official data
202200 hours99.9%Official data
202100 hours99%Official data

A missing figure means the source did not provide a usable value. A zero is shown as zero. Monitor operation below 90% can make comparison less reliable.

Outlet details

Water company
Southern Water
Outlet type
Storm discharge at a pumping station
Permit
W00551
Activity reference
Storm
Grid reference
TQ7191066980
Waterbody ID
GB530604002300Official waterbody record ↗
Location source
Official annual grid reference
Location precision
About 1 metres
Location note
Unknown

About the name and type

The annual return lists this asset as “Storm discharge at pumping station”: storm discharge at a pumping station. The overflow is at a pumping station that moves sewage through the network.

The source name includes CEO, which Southern Water defines as Combined Emergency Overflow. The name and the listed type are separate source fields, so the name does not describe the layout of the site. Southern Water flow and spill reporting glossary ↗

The waterbody link opens the Environment Agency record for the exact ID in the return. It is a source lookup; we do not import its classification.

Where it is

The recorded position is about 1.3 km east of the Cuxton reference point in the ONS built-up areas data.

Area and water pages

Check the official record

Public access to this outlet is unknown. Do not enter restricted land or use this page as a route guide.

Open official source ↗

Other outlet records nearby

Questions about Cuxton CEO - 111607

Who operates Cuxton CEO - 111607?
Southern Water is the operator named in the annual record. The permit reference is W00551.
Where does Cuxton CEO - 111607 discharge?
The source names The Tidal River Medway as the receiving water. This does not show how far a discharge travelled.
How many times did Cuxton CEO - 111607 spill in 2025?
The 2025 return records 0 counted spill events and 0 hours of recorded discharge. Spills are counted with the 12/24-hour method, so this is not a count of every start signal.
Can I trust the 2025 figures for this outlet?
The monitor worked for 100% of the reporting period, so the annual figures cover most of the year. They still do not measure discharge volume.
Is Cuxton CEO - 111607 discharging right now?
This record is not matched to a company live feed, so we cannot show a current report. Only the annual figures are available for this outlet.
How accurate is the map marker?
The marker comes from the grid reference in the official annual return, which is accurate to about 1 metres. It shows the recorded outlet position, not the extent of any discharge.
What kind of outlet is Cuxton CEO - 111607?
The annual return lists the asset type as “Storm discharge at pumping station”, which means storm discharge at a pumping station. The overflow is at a pumping station that moves sewage through the network. The source name includes CEO, which Southern Water defines as Combined Emergency Overflow. The name and the listed type are separate source fields.
How does Cuxton CEO - 111607 compare with other overflows?
Cuxton CEO - 111607 recorded no spills in 2025. It is one of 2,231 overflows in England with a reported count of zero, out of 14,239 with a count. Ranks compare counted spill events only. They do not compare volume or harm.
Does zero spills mean the water was safe?
No. A zero means the annual return recorded zero counted spill events for this outlet and year. It is not a water-quality test, and pollution can come from other sources.