Sewage Map

Belford Sewage Treatment Works, Northumbrian Water (221/1034 · A3 · NWL00111)

Storm overflow operated by Northumbrian Water. The source names Belford Burn as the receiving water.

2
Spills in 2025
15.5
Recorded hours
6.2%
Monitor operation
2
Years listed
Current status unknown

Checking the latest monitor report…

Open official annual data ↗

How it compares in 2025

Belford Sewage Treatment Works, Northumbrian Water (221/1034 · A3 · NWL00111) recorded 2 spills in 2025. That is more than 21% of the 14,239 overflows in England with a reported figure, and ranks 10,428th nationally. Among Northumbrian Water overflows it ranks 1,127th of 1,559; the median Northumbrian Water overflow recorded 11 spills. On the Belford Burn from Source to Ross Low waterbody it ranks 3rd of 3.

The monitor worked for 6.2% of 2025, so this count may be low and its rank may understate activity.

GroupRank by spillsMedian spillsMedian hours
This outlet–215.5
England10,428th of 14,2391122.3
Northumbrian Water1,127th of 1,5591115.6
Belford Burn from Source to Ross Low3rd of 32333

Rank 1 has the most spills. Equal counts share a rank. Only overflows with a reported count are ranked. Counts do not measure volume, so a higher rank does not mean more sewage.

Annual spill history

91202422025
From 2024 to 2025, the reported count went from 91 to 2 spills. The highest count was 91 in 2024 and the lowest was 2 in 2025. The monitor worked for less than 90% of 2025, so that count may be low.Amber bars mark years when the monitor worked for less than 90% of the year.
YearSpillsDurationMonitor operationSource
2025215.5 hours6.2%Low coverageOfficial data
2024911,349 hours93.2%Official data

A missing figure means the source did not provide a usable value. A zero is shown as zero. Monitor operation below 90% can make comparison less reliable.

Outlet details

Water company
Northumbrian Water
Outlet type
Storm tank at a wastewater treatment works
Permit
221/1034
Activity reference
A3
Grid reference
NU1171033885
Waterbody ID
GB103022076460Official waterbody record ↗
Location source
Official annual grid reference
Location precision
About 1 metres
Location note
Unknown

About the name and type

The annual return lists this asset as “Storm tank at WwTW”: storm tank at a wastewater treatment works. The overflow comes from storm storage at a treatment works.

The waterbody link opens the Environment Agency record for the exact ID in the return. It is a source lookup; we do not import its classification.

Where it is

The recorded position is about 0.9 km east of the Belford reference point in the ONS built-up areas data.

Area and water pages

Check the official record

Public access to this outlet is unknown. Do not enter restricted land or use this page as a route guide.

Open official source ↗

Other outlet records nearby

Questions about Belford Sewage Treatment Works, Northumbrian Water (221/1034 · A3 · NWL00111)

Who operates Belford Sewage Treatment Works, Northumbrian Water (221/1034 · A3 · NWL00111)?
Northumbrian Water is the operator named in the annual record. The permit reference is 221/1034.
Where does Belford Sewage Treatment Works, Northumbrian Water (221/1034 · A3 · NWL00111) discharge?
The source names Belford Burn as the receiving water. This does not show how far a discharge travelled.
How many times did Belford Sewage Treatment Works, Northumbrian Water (221/1034 · A3 · NWL00111) spill in 2025?
The 2025 return records 2 counted spill events and 15.5 hours of recorded discharge. Spills are counted with the 12/24-hour method, so this is not a count of every start signal.
Can I trust the 2025 figures for this outlet?
The monitor worked for 6.2% of the reporting period. Below 90%, some events can be missed, so the count and hours may understate activity.
Is Belford Sewage Treatment Works, Northumbrian Water (221/1034 · A3 · NWL00111) discharging right now?
This record is linked to a company live feed. The panel above shows the latest report we hold, with its date. That report can be old, and the monitor can be offline, so check the date before relying on it. A report that no discharge is taking place is not a water-quality result.
How accurate is the map marker?
The marker comes from the grid reference in the official annual return, which is accurate to about 1 metres. It shows the recorded outlet position, not the extent of any discharge.
What kind of outlet is Belford Sewage Treatment Works, Northumbrian Water (221/1034 · A3 · NWL00111)?
The annual return lists the asset type as “Storm tank at WwTW”, which means storm tank at a wastewater treatment works. The overflow comes from storm storage at a treatment works.
How does Belford Sewage Treatment Works, Northumbrian Water (221/1034 · A3 · NWL00111) compare with other overflows?
Belford Sewage Treatment Works, Northumbrian Water (221/1034 · A3 · NWL00111) recorded 2 spills in 2025. That is more than 21% of the 14,239 overflows in England with a reported figure, and ranks 10,428th nationally. Among Northumbrian Water overflows it ranks 1,127th of 1,559; the median Northumbrian Water overflow recorded 11 spills. On the Belford Burn from Source to Ross Low waterbody it ranks 3rd of 3. Ranks compare counted spill events only. They do not compare volume or harm.
Does zero spills mean the water was safe?
No. A zero means the annual return recorded zero counted spill events for this outlet and year. It is not a water-quality test, and pollution can come from other sources.